应用CAE技术评价VIP对冰箱能效的改善.pdfVIP

  • 10
  • 0
  • 约1.14万字
  • 约 5页
  • 2017-08-17 发布于安徽
  • 举报

应用CAE技术评价VIP对冰箱能效的改善.pdf

201 1年中国家用电器技术大会·论文集III 应用CAE技术评价VIP对冰箱能效的改善 陈士发韩雷 文坚 (美的制冷集团冰箱事业部,230601) 摘 要:本文以某型号冰箱为例,通过CAE仿真冰箱箱体的保温性能和箱内的开停机状态,并对比分析冰箱加装不 同厚度真空绝热板(VIP)时的冰箱性能参数。结果表明CAE软件能够准确预估冰箱性能参数。与原模型相比,泡层内分 VIP应用于冰箱能耗改善提供了强有力的设计工具。 关键词:冰箱能耗真空绝热板 CAEEvaluationsofthe of EnergyConsumption withVacuumInsulation Refrigerators Panels(VIPs) Chen Jian Shifa,HanLei,Wen (Midea Divison,230601) Refrigeration Abstract:Basedonacurrent modelof CAEsimulationiscarriedoutto the refrigeratorMidea,a predict heatflowin transientstateof and effects steadystate,and refrigeratorduringoperatingrestingprocesses.The are on withVIPsofdifferent comparedenergy thicknesses.Theresultsshowthatthe of consumption prediction refrigerator’senergy isaccuratewhen withthetestresults.CAEmodelsshowthatheat consumption compared rateand arealldecreasedwhena 10or20mmVIPareused. loss,compressoroperating energyconsumption Theheatlossesaredecreased11.2%and 16.0%and by 9.7%respectivelyduringresting processes.whereas ratesof are35.I%without 13.7%respectivelyduringoperatingprocesses;Theoperating compressor VIP, 27.4%with10mmVIPand23.3%with20ramVIP standsforan of respectively:whichenergyconsumption