小电流接地系统中单相接地故障的判断与处理(Judgment and treatment of single phase to ground fault in small current grounding system).docVIP
- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
小电流接地系统中单相接地故障的判断与处理(Judgment and treatment of single phase to ground fault in small current grounding system)
Judgment and treatment of single phase to ground fault in small current grounding system
A small current neutral grounding system is a system that uses neutral grounding or arc suppression coils to ground. In this system, such as the single-phase ground, due to the size and phase line voltage unchanged (still symmetric), and the system is designed according to the insulation of the line voltage, so allow short run without cutting equipment failure, so as to improve the reliability of power supply. However, if one phase is grounded, the other two relative voltage rises to J3 times the phase voltage, especially when intermittent arcing occurs, and the ground relative voltage may rise to 2.5 - 3 times the phase voltage. This over-voltage threatens the security of the system and may cause one phase insulation breakdown to cause a two phase grounding short circuit fault. Therefore, the duty officer should quickly find the ground and isolate it in time.
When the neutral point is not earthed directly, the following signs usually appear:
(1) the alarm went x x kV Bus grounding bright light plate, personality Petersen coil grounded system, there are often Petersen coil action bright light plate.
(2) the three-phase indication value of the insulation monitor voltmeter is different, the ground phase voltage is reduced or equal to zero, and the other two phase voltage rises to the line voltage, and this is the stability grounding. If the insulation monitor voltmeter swings back and forth, this phenomenon is intermittent grounding.
(3) when the arc grounding overvoltage, non fault phase voltage is very high, hands to the head, often accompanied by a voltage transformer high voltage side fusing, and even seriously burned out voltage transformer.
When the small current grounding system of the occurrence of the signs, the duty should be calm, report to the superior dispatc
您可能关注的文档
- 如何降低聘请外表明星的风险(How to reduce the risk of hiring appearance stars).doc
- 如何降低销售人员的流失率(How to reduce the turnover rate of sales staff).doc
- 如何解决激光打标机刻字体变形(How to solve the deformation of laser marking machine).doc
- 如何解决电脑蓝屏!(How to solve the blue screen of computer!).doc
- 如何戒SY(How to quit SY).doc
- 如何进行网站运营数据分析(How to analyze website operation data).doc
- 如何进行网站诊断 为网站进行评分(How do you conduct a site diagnosis and score a website).doc
- 如何解男孩的恋母情结和女孩的恋父情结的模型法探讨(A model approach to solving the Oedipus complex and the Electra complex of a girl).doc
- 如何经营酒店(How to manage a hotel).doc
- 如何精准评估培训效果(How to evaluate training effectiveness accurately).doc
原创力文档


文档评论(0)