TEG Dehydration Unit Sizing Design Guide Document No: KS-PR-DEG-0151 Rev 0 01 December 2019 © Copyright 2019 Worley ACN 096 090 158. No part of this document or the information it contains may be reproduced or transmitted in any form or by any means electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without permission in writing from Worley. Table of Contents 1. Introduction 3 2. Dehydration 3 3. TEG Dehydration Unit 4 3.1 Process Design Factors5 3.1.1 Water Content 5 3.1.2 Minimum Lean TEG Concentration 6 3.1.3 TEG Circulation Rate – Absorber Contact 7 3.2 Contactor 7 3.3 Regeneration8 3.3.1 Column 8 3.3.2 Reboiler 9 3.3.3 Surge Drum 9 3.4 Flash Tank 9 3.5 Exchangers 9 3.6 Pumps 10 3.7 Filters 10 3.8 Heat and Mass Balances 10 4. High Performance Regeneration Processes 10 4.1 Stripping Gas 10 4.2 Vacuum 11 4.3 Cold finger Process11 4.4 DRIZO Process 11 5. Emissions 11 6. Glycol Losses 11 7. References 12 TEG Dehydration Unit Sizing Design Guide ii KS-PR-DEG-0151 Rev 0 01 December 2019 1. Introduction The intent of this document is to provide a guideline for sizing the major pieces of equipment in a TEG Dehydration Package. The discussions in this document are to serve as an overview on the subject. For more detailed discussions on the topic, please refer to the reference material. 2. Dehydration