网站大量收购独家精品文档,联系QQ:2885784924

全髋关节置换手术记录(Total hip replacement surgery records).doc

全髋关节置换手术记录(Total hip replacement surgery records).doc

  1. 1、本文档共17页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
全髋关节置换手术记录(Total hip replacement surgery records)

全髋关节置换手术记录(Total hip replacement surgery records) After the anesthesia was successful, the patients were treated with left lateral decubitus and fixed position frame. Routine iodine, alcohol disinfection of wild skin, sterile towel. The posterolateral incision of right hip joint was about 12cm, incision of skin and subcutaneous tissue, and hemostasis by electrocoagulation. Incision of fascia lata, revealed the greater trochanter, to the greater trochanter after blunt dissection of gluteus muscle gap and hip, protect the sciatic nerve, retraction of gluteal muscle, expose the external rotators in intertrochanteric fossa, cut off the external rotators (piriformis and obturator muscle, muscle larvae and gemellus), marked with purple line. The small trochanter was revealed along the periosteum of the femur and exposed to the joint capsule of the hip. The posterior articular capsule was incised and marked with a purple line. Flexion of the internal rotation of the hip joint exposes the femoral head and causes dislocation of the femoral head. See femoral head collapse, deformation, lose normal shape. Remove the base of the femoral neck in fibrous tissue, small trochanter 1.5cm vertical with a chainsaw amputated femoral head in the femoral neck and femoral neck, remove the femoral head. The plate retractor reveals the acetabulum. Removal of the bony margin of the acetabulum and loosening of the fibrous tissue around the joint. Excision of soft tissue in acetabulum. Followed by the 44mm-54mm file to maintain 45 degrees valgus anteversion of acetabular acetabular acetabular of 15 degrees of grinding, the true acetabulum bottom, and subchondral bone errhysis, hemostasis rinse the acetabulum, to test the size and direction of test model of acetabular acetabular well. The acetabular component of the cementless 56mm (LINK artificial hip joint) was cemented at 45 degrees of anteversion and 15 degrees, and two screws were firmly fixed. Into the high molecular polyethylene liner. D

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档