Technical Service Request
TSR ID : Status : New
Business Segment : CCA Request Placed : 2007-03-12 Product Name : XH111 Normal, Araldite Standard Target Date : Customer : Chengdu Action Started : 2007-03-14 Project Title : Action Finished : 2007-03-16 Requested By : Matthew Yang Conducted By : lentil chan Request Type : Customer service Approved By :
1. Background
Customer want to know the bonding performance of concrete and insulating board, using XH111 Normal.
2. Proposed Actions
2.1 Test pull-of Strength of XH111 Normal bonding with concrete and insulating board
1) Cut insulating board into circle shape, diameter=13mm
2) Using XH111 Normal, to bond insulating board on concrete(Type: C30)
3) Using Araldite Standard, to bond dolly on the insulating board.
4) Curing schedule: 16hrs @ 40oC
5) Surface treatment:
contrete: grinding; dolly: sandblasting; insulating board: solvent wipe
3. Results and Discussion
3.1 Result
Product Pneumatic adhesion [MPa] Broken point XH111 Normal A/B 2.55 substrate failure (concrete)
4. Conclusion and Recommendations
4.1 XH111 Normal provide a strong bonding for concrete / Insulation broad in term of pull off test (substrate failure).
5. Remarks
Below are the boding sample before pull-of test and after pull-off test:
Prepared by: (lentil chan)