美国FDA指导原则 Addendum to Guidance on Premarket Notification [510(k)] Submissions for Sterilizers Intended for Use in Health Care Facilities (Text Only).docxVIP

美国FDA指导原则 Addendum to Guidance on Premarket Notification [510(k)] Submissions for Sterilizers Intended for Use in Health Care Facilities (Text Only).docx

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Addendum to: Guidance on Premarket Notification [510(k)] Submissions for Sterilizers Intended for Use in Health Care Facilities (Text Only) Share Tweet Linkedin Pin it More sharing options Linkedin Pin it Email \o Print this page Print This guidance was written prior to the February 27, 1997 implementation of FDA’s Good Guidance Practices, GGP’s. It does not create or confer rights for or on any person and does not operate to bind FDA or the public. An alternative approach may be used if such approach satisfies the requirements of the applicable statute, regulations, or both. This guidance will be updated in the next revision to include the standard elements of GGP’s ? DATE:???? September 19, 1995 FROM:???? Acting Director, Pilot Division, DDIG (HFZ-420)____ SUBJECT:?Addendum to the Sterilizer Guidance Document TO:?????? DSMA ? The purpose of this memo is to amend the Guidance on Premarket Notification [510(k)] Submissions for Sterilizers Intended for Use in Health Care Facilities, dated March 1993, to provide the following: ? 1.?? clarification of the types of test data required for steam and dry-heat?sterilizers with sterilization cycle parameters which differ from the?traditional sterilization cycle parameters (e.g., for steam, temperatures?other than 121o and 132o C; and for dry heat, 160o and 190o C); 2.?? clarification of simulated-use and in-use testing requirements for?traditional sterilizers; and 3.?? clarification of the types of organic loads which are acceptable for?simulated use performance testing. ? Steam and Dry-Heat Sterilizers with Sterilization Cycle Parameters Which Differ From the Traditional Sterilization Cycle Parameters: ? FDA has received 510(k) submissions for steam and dry heat sterilizers, especially table top steam sterilizers, describing new cycle parameters which differ from the traditional cycle parameters of preamendment or previously cleared steam and dry heat sterilizers.?Usually the descriptions of the

您可能关注的文档

文档评论(0)

千年硕鼠 + 关注
实名认证
文档贡献者

药学医师证持证人

10年深耕医疗器械、体外诊断试剂领域

版权声明书
用户编号:5014214200000130
领域认证该用户于2023年05月20日上传了药学医师证

1亿VIP精品文档

相关文档