- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
U型地埋管换热器换热性能模拟及试验研究-供热供燃气通风及空调工程专业论文
西南科技大学硕士研究生学位论文 第 II 页
Abstract
Ground source heat pump which absorbs heat(cold) from the shallow soil is the most friendly to the environment and most effective cooling(heating) mode in the current circumstances. In recent years, people gradually increased the research of heat pump technology, and how to improve the thermal performance of heat exchanger is becoming a research focus.
The paper based on the new energy renovation project of southwest university of science and technology. First of all, according to the requirement of the relevant technical specifications, using professional geotechnical t hermal response test instrument , test the single and double U buried tube heat transfer performance . The most commonly used
method of slope in engineering is adopted to analyze the test da ta,obtained soil coefficient
of thermal conductivity , volumetric heat capacity and the borehole thermal resistance .
Then use test measured soil initial temperature, the return water temperature and flow rate of u-type underground heat exchanger, power consumption and other data to calculate , The results sho wed that double u-type heat exchanger’s per linear meter in heat and energy efficiency were higher than single u-type.
Finally, the numerical simulation method was carried out on the heat transfer performance of the u-type heat exchanger. Inputting test measured thermal physical parameters in the 3d model which is exactly the same as the actual, simulation results are in good agreement with measured test data, verifying the correctness of the model . The influence of the inlet velocity and temperature, the depth of the drilling, backfill materials and the initial soil temperature were obtained by dynamic simulation. Research pointed out that the design of the fluid inlet temperature should be comprehensive consideration of the system energy efficiency coefficient and heat transfer, the design flow rate for 0.4~0.6 m/s advisable, drilling depth take 60 m t
您可能关注的文档
- Trps1负向调控EMT对移植肝胆管纤维化的影响-普通外科学专业论文.docx
- TRPM7对内质网应激诱导类风湿性关节炎成纤维样滑膜细胞凋亡的调控作用研究-中药学专业论文.docx
- TRPV1下调对神经病理性疼痛的保护作用及其作用机制研究-外科学(骨外)专业论文.docx
- TRT叶片拉金结构力学特性及减振分析-机械制造及其自动化专业论文.docx
- TRT在男性迟发性性腺功能减退症伴轻中度前列腺增生的应用-外科学(泌尿外科)专业论文.docx
- TRT叶片表面积灰对其力学性能的影响研究-机械制造及其自动化专业论文.docx
- TRU公司内部控制研究-工商管理专业论文.docx
- TRU公司在华经营战略研究-工商管理专业论文.docx
- TRU公司精益物流供应链管理研究-物流管理专业论文.docx
- TRT叶片阻尼结构设计及减振性能研究-机械制造及其自动化专业论文.docx
- U型地埋管换热器换热性能的边界元法分析-固体力学专业论文.docx
- U型玻璃管中浆体流变参数的研究-材料学专业论文.docx
- U型液压系统关键零部件的优化设计和制造过程控制-车辆工程专业论文.docx
- U型管蒸汽发生器仿真模型及动态特性研究-热能工程专业论文.docx
- U大学后勤集团HR改革试点项目的范围和时间管理-项目管理专业论文.docx
- U形直线超声电机设计和实验及其并联性能研究-机械设计及理论专业论文.docx
- U形风道引鼓风组合式冷凝器设计及蒸发管外传热的实验-动力工程专业论文.docx
- U波段混频技术研究-电磁场与微波技术专业论文.docx
- U盘的文件存储加密-软件工程专业论文.docx
- V1购物广场开发项目风险管理研究-项目管理专业论文.docx
文档评论(0)