网站大量收购独家精品文档,联系QQ:2885784924

《Interface for Online Coupling of Surface Plasmon Resonance to Direct Analysis in Real Time Mass Spectrometry》.ppt

《Interface for Online Coupling of Surface Plasmon Resonance to Direct Analysis in Real Time Mass Spectrometry》.ppt

  1. 1、本文档共11页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Da-Pinker Litrature report * Interface for Online Coupling of Surface Plasmon Resonance to Direct Analysis in Real Time Mass Spectrometry * Authors:Yiding Zhang, Xianjiang Li, Honggang Nie, Li Yang, Ze Li, Yu Bai, Li Niu, Daqian Song, and Huwei Liu . Published :Analytical-Chemistry(June 11, 2015) Proper noun SPR:surface plasmon resonance 1 DART:direct analysis in real time 2 * Background 1. SPR is a powerful technique widely utilized in the studies based on interaction processes such as cellular analysis and clinical research but the insufficiency in qualitative analysis. 2. MS is an extraordinary technique in qualitative analysis. 3.Schematic diagram of SPR Experimental * 1. DART was coupled to the MS after removing the original electrospray ion source and connecting a vacuum pump . 2. Sprayer was attached onto a 3D platform via a homemade holder. * Experimental Test the feasibility and the tolerance of salts First 2 min, pure solvent was delivered. At the beginning of the third minute, the sample solution started to flow and lasted for 4 min. From the sixth minute, the pure solvent was delivered. After the SPR signal fell back to its baseline and the MS signal became stable, the acquisition was stopped. Results Discussion The significance of the parameters were as follows: d 3 nebulizing gas pressure temperature flow rate d 1 D2(horizontal distance between the spray tip and the MS inlet) could not be included in the orthogonal experiments. Helium could give a better signal Results Discussion For the first 2 min , SPR signal stayed at its baseline,so did the MS signal. At the third minute, SPR signal started to increase,So did MS signal. From the sixth minute, SPR signal changed to its original values,So did MS signal. Factors of observable lag: 1.All of these volumes between the pump and the MS. 2. Remainedanalytes bound on the sensor chip. 3. Incomplete droplets. Results Discussion Relative intensities of the quasi-molecular ion

您可能关注的文档

文档评论(0)

1318384917 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档